![AMCC 3ware 9000 Series User Manual Download Page 180](http://html1.mh-extra.com/html/amcc/3ware-9000-series/3ware-9000-series_user-manual_2921145180.webp)
Troubleshooting: Problems and Solutions
174
3ware 9000 Series Serial ATA RAID Controller User Guide
AEN 046h AEN_VOLTAGE_HIGH_WARN
The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage is above a warning threshold, this AEN will
be posted to the user. When this event happens, the Battery backup Unit is still
able to backup the 3ware RAID controller but the user should replace the
battery.
AEN 047h AEN_VOLTAGE_BELOW_OPERATING
The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage is too low to operate, this AEN will be
posted to the user. This indicates that the battery pack must be replaced. The
Battery Backup Unit becomes not ready and is unable to backup the 3ware
RAID controller.
AEN 048h AEN_VOLTAGE_ABOVE_OPERATING
The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage is too high to operate, this AEN will be
posted to the user. The Battery Backup Unit becomes not ready and is unable
to backup the 3ware RAID controller. This indicates that the Battery Backup
Unit must be replaced.
AEN 049h AEN_TEMPERATURE_NORMAL
The Battery Backup Unit measures and evaluates the battery pack
temperature on a continuous basis. If the temperature falls outside the
acceptable range then comes back within the acceptable range, this AEN will
be posted to the host.
AEN 04Ah AEN_TEMPERATURE_LOW_WARN
The Battery Backup Unit measures and evaluates the battery pack
temperature on a continuous basis. If the temperature is below a warning
threshold, this AEN will be posted to the user. When this event happens, the
Battery Backup Unit is still able to backup the 3ware RAID controller but the
user should replace the battery pack.
AEN 04Bh AEN_TEMPERATURE_HIGH_WARN
The Battery Backup Unit measures and evaluates the battery pack
temperature on a continuous basis. If the temperature is above a warning
threshold, this AEN will be posted to the user. The user should check that
there is enough airflow around the Battery Backup Unit. When this event
happens, the Battery Backup Unit is still able to backup the 3ware RAID
controller but the user should replace the battery pack if the temperature
warning persists.
Summary of Contents for 3ware 9000 Series
Page 1: ...3ware Serial ATA RAID Controller Supports the 9000 Series PN 720 0114 01 March 2005 User Guide...
Page 10: ...About This Guide 4 3ware 9000 Series Serial ATA RAID Controller User Guide...
Page 88: ...Configuring Your Controller 82 3ware 9000 Series Serial ATA RAID Controller User Guide...
Page 144: ...Maintaining Units 138 3ware 9000 Series Serial ATA RAID Controller User Guide...
Page 190: ...Glossary 184 3ware 9000 Series Serial ATA RAID Controller User Guide...