![AMAZONEN-Werke EK-S 150 Operation Manual Download Page 36](http://html1.mh-extra.com/html/amazonen-werke/ek-s-150/ek-s-150_operation-manual_2919839036.webp)
Assembly and function
36
EK-S/EK-SH BAG0022.4 07.22
5.1
Shutter actuation
Manual or hydraulic (option) opening and closing
of the outlet opening via 2 shutters.
Manual shutter actuation:
•
For
closing
the outlet opening swivel the
hand lever (Fig. 9/1) right to the top.
•
For
opening
the outlet opening swivel the
hand lever downwards (Fig. 9/1) until the
stop of the spread rate adjustment.
Fig. 9
Hydraulic shutter actuation:
•
Opening
of the outlet opening via tension-
ing spring (Fig. 10/1),
•
Shutting
of the outlet opening hydraulically
via one single acting hydraulic ram
(Fig. 10/2).
Fig. 10
Fig. 11/...
•
Shutter
A
•
Shutter
B
When spreading
fertiliser
according to the ad-
vice in the spreading chart Seite 75.
•
both shutter slides are open,
•
shutter slide
A
is closed,
•
shutter slide
B
is closed.
If it is intended to keep one shutter slide closed
during operation unhook the relevant switch rod
(Fig. 11/1).
1. Pull spring cotter (Fig. 11/2).
2. Pull the switch rod off the hinged pin.
3. Re-insert spring cotter.
4. Secure the position of the unhooked switch
rod with the aid of the PTO shaft chain.
Fig. 11