Layout and function of the sprayer boom
UX01 Super CP Plus BAG0229.2 11.21
105
Pressure circulating system (DUS)
•
For normal spraying operation, the pressure circulating system
should always be switched on.
•
When using drag hoses, the pressure circulating system should
always be switched off.
The pressure circulating system
•
enables the constant circulation of liquid in
the spray line. To do so, a suction port hose
(1) is assigned to each part-width section.
•
can be operated using spray liquid or
flushing water, as desired.
•
reduces the undiluted residue for all spray
lines to 2 l.
The constant circulation of liquid
•
enables production of a uniform spray
pattern right from the start, because spray
liquid is available at every spray nozzle
immediately after the sprayer boom is
switched on, with no delay.
•
prevents damage to the spray line.
Line filter for spray lines (optional)
The line filter (1) is
•
installed in the spray lines in each part-
width section (part-width section control).
•
installed in the spray lines on the left and
right (single nozzle control)
•
an additional measure to prevent
contamination of the spraying nozzles.
Overview of the filter inserts
•
Filter insert with 50 mesh/inch (blue)
•
Filter insert with 80 mesh/inch (grey)
•
Filter insert with 100 mesh/inch (red)