Cleaning, maintenance and repairs
UX01 Super CP Plus BAG0229.2 11.21
207
14.5.1 Automatic load-dependent braking force regulator (ALB)
Check the brake pressure:
connect a pressure gauge to the test connection
on the brake cylinder.
if the brake pressure deviates from the required
values, set the brake pressure on the ALB via
the eye bolts.
1. Container empty: set dimension X until
the brake pressure of 3.5 bar is reached.
•
Unscrew the eye bolt.
→
The test pressure reduces
•
Screw in the eye bolt.
→
The test pressure increases
2. Container at nominal volume minus 10 to
15 %: set dimension Y until the brake
pressure of 6.5 bar is reached.
•
Unscrew the eye bolt
→
The test pressure increases
•
Screw the eye bolt in
→
The test pressure reduces
14.5.2 Hydraulic brakes
Check of the hydraulic brake
•
Check all brake hoses for wear
•
check all screw unions for seal tightness
•
renew any worn or damaged parts.
Venting the brake system (workshop work)
After each brake repair, for which the system has
been opened, bleed the brake system, because
air may have entered the pressure hoses.
1. Slightly loosen the vent valve.
2. Actuate the tractor brake.
3. Close the vent valve as soon as oil
escapes.
→
Collect the escaping oil.
4. Perform a brake check.