14.13 Electro hydraulic boom
WARNING
DistanceControl, ContourControl
Risk of injury due to accidental movement of the sprayer boom
in automatic mode when entering the radiation area of the
ultrasound sensor.
Lock the sprayer boom
•
Before leaving the tractor.
•
If unauthorised persons are standing in the area of the sprayer
boom.
(1) Ultrasound sensors for boom tilt
(2) Yaw rate sensor for boom tilt
(3) Potentiometer for boom tilt
(4) Potentiometer for boom folding
(5) Hydraulic block with manual emergency folding function
Emergency folding function for the outer boom sections
In case of defective wiring harness, the boom sections can be
hydraulically folded by manual actuation of the hydraulic block (5a, b,
c).
→
Control terminal is switched on, oil circulation is active.
•
Press the button on both solenoids 5a: outer boom section is
folded.
•
Press the button on both solenoids 5b: 2nd boom section from
the outside is folded.
•
Press the button on both solenoids 5c: 3rd boom section from
the outside is folded.
Emergency folding with intact electronics:
See ISOBUS operating manual / settings / implement.