Cleaning, maintenance and repair
KG 4/5/6001-2 BAH0060-5 12.17
123
12.6 Two-gear
gearbox
Venting
The gearbox is equipped with a ventilation valve (Fig. 132/1).
Ventilation must be ensured to prevent the gearbox from developing
leaks.
Check the oil level
1. Park the implement on a level surface.
Fig. 132
When the fill quantity is correct, the oil level
is visible in the oil sight glass (Fig. 132/2).
2. If necessary, add transmission fluid through
the opening in the breather (Fig. 132/1).
Changing transmission fluid (specialist workshop)
1. Place a suitable container below the oil
drain opening.
2. Unscrew the oil drain screw (Fig. 132/3).
3. Collect the transmission fluid and dispose of
it properly.
4. Screw in the oil drain screw.
5. Refill with new transmission fluid
(for oil types and fill quantities, see the
section "Technical Data").
6. Screw in the breather.