23
EN
• If the measured circuit or component is
electrically open, the display (F) shows
OL
.
• If the resistance is <50 Ω, beeping tone alerts
that low resistance is measured. The stabilized
value on the display (F) is read as the actual
reading.
Diode test
• Insert the black connector lead (P) into the
negative
COM
(black) terminal (I) and the red
connector lead (P) into the positive
V
(red)
terminal (J).
• Set the function switch (L) to the
/CAP
position.
• Press the
MODE
button (H) to change the
measurement mode. The indicator (7) is
shown on the display.
• Connect the test probes (P) across the diode
being measured.
• If the diode was measured in reverse, the
display (F) shows
OL
. Reverse the probes (P)
position to get the correct polarity.
• The stabilized value on the display (F) is read
as the approximate forward voltage drop of the
diode.