20
EN
• Set the function switch (L) to the
Ω
/
position.
• Connect the test probes (P) across the circuit
or component being measured. It is best to
disconnect one side of the device being tested
so the rest of the circuit does not interfere with
the resistance reading.
• If
OL
appears on the display (F), no current flow
can be measured because the circuit is open or
the resistance is too high to measure.
• The stabilized value on the display (F) is read as
the actual reading.
Capacitance measurement
NOTICE
To avoid electric shock or
measurement errors, discharge the capacitor
under test before measuring.
• Insert the black connector lead (P) into the
negative
COM
(black) terminal (I) and the red
connector lead (P) into the positive
V
(red)
terminal (J).
• Set the function switch (L) to the
/CAP
position.
• Press the
MODE
button (H) to shift to
measuring the capacitance
F
(Farad).
• Connect the test probes (P) to the capacitor
being measured.