19
EN
Measuring AC voltage peaks
• In AC voltage measurement mode, press
the
MAX/MIN
button (K) to switch between
the maximum (
MAX
) and minimum (
MIN
)
measured value. The
MAX
/
MIN
indicator (9) is
shown on the display (F).
• Press the
MAX/MIN
button for 2 seconds to
return to normal operation. The
MAX
/
MIN
indicator goes off.
DC voltage measurement
• Insert the black connector lead (P) into the
negative
COM
(black) terminal (I) and the red
connector lead (P) into the positive V (red)
terminal (J).
• Set the function switch (L) to the position.
• Connect the test probes (P) in parallel to the
component or circuit being measured.
• The stabilized value on the display (F) is read as
the actual reading.
Resistance measurement
• Insert the black connector lead (P) into the
negative
COM
(black) terminal (I) and the red
connector lead (P) into the positive
V
(red)
terminal (J).