22
EN
Resistance measurement
• Insert the black connector lead (S) into the
negative
COM
(black) terminal (I) and the red
connector lead (S) into the positive
V
(red)
terminal (M).
• Set the function switch (K) to the
Ω/CAP
position.
• Connect the test probes (S) across the circuit
or component being measured.
• If
OL
appears on the display (F), the circuit or
device being tested is open or has a resistance
that is above the range of the product.
• The stabilized value on the display (F) is read as
the actual reading.
Capacitance measurement
• Insert the black connector lead (S) into the
negative
COM
(black) terminal (I) and the red
connector lead (S) into the positive
V
(red)
terminal (M).
• Set the function switch (K) to the
Ω/CAP
position.
• Press the
MODE/VFD
button (H) to shift to
measuring the capacitance
F
(Farad).
• Connect the test probes (S) across the circuit
or the capacitor being measured.