30
EN
DC current
Range
Resolution
Accuracy
60 A
10 mA
±2.0 % f.m.* ±8 digits
600 A
100 mA
±2.5 % f.m.* ±8 digits
Overrange protection: Maximum input 600 A.
AC true rms voltage (with VFD)
Range
Resolution
Accuracy
6 V
1 mV
±1.2 % f.m.* ±5 digits
60 V
10 mV
600 V
100 mV
1000 V
1 V
±1.5 % f.m.* ±5 digits
• Variable frequency drive measurement
AC voltage range: 100 V – 600 V.
• AC voltage bandwidth:
50 to 1000 Hz (sinusoidal);
50/60 (all waves)
• Accuracy specified from 5 % to 100 % of the
measuring range.
• Maximum input: 1000 V AC rms.
• PEAK maximum input: 1000 V.