27
EN
NOTICE
For longer period of measurements,
use a thermal tape to attach the thermocouple
probe to the surface being measured.
NOTICE
Risk of product damage!
Disconnect the thermocouple probe (Q) before
changing to other electrical measurement mode.
Non-contact voltage measurement
WARNING
Risk of electric shock!
Before
use, always test the voltage detector on a known
live circuit to verify proper operation.
NOTICE
Insulation type and thickness,
distance from the voltage source, shielded wires,
and other factors may effect reliable operation.
Use other methods to verify live voltage, if there is
any uncertainty.
NOTICE
Non-contact voltage detection
(100 V to 600 V AC).
• Touch the non-contact probe tip (A) to the
electrical device or live conductor being
checked.
• If the product detects voltage within the
defined detection range, the detector indicator
(C) lights up.