16
EN
Display hold
• To freeze the display reading, press the
H /
button (J). The
H
indicator (9) appears.
• Press the
H /
button (J) again to return to
normal operation.
Changing the measurement range
By default, the measurement range is set
automatically and the
AUTO
indicator (6) appears.
It is possible to set the measurement range
manually (not in every measurement mode).
• Press the
RANGE
button (G) to activate
the manual mode and to disable the
automatic range setting. The
AUTO
indicator
(6) disappears.
• By every press on the
RANGE
button (G) the
relevant decimal place changes its position.
• If a reading is higher than the measurement
range,
OL
appears on the display (F).
• Press and hold the
RANGE
button (G) for
more than 1 second to exit manual mode and
restore automatic range setting. The
AUTO
indicator (6) appears.