1200
,
2400
,
4800
,
9600
,
19.2
,
38.4
,
57.6
,
115.2
Baud rates above 9600 are in k Baud.
5.99
Serial parity
Section:
SErI
Display:
PrtY
Range:
8 N
,
8 E
,
8 O
,
7 E
,
7 O
Default Value:
8 N
Default Access Level
4
Function number
4482
Allows selection of the parity check. The parity check selected should match that of the device it is being commu-
nicated with. The choices are 8 bit with no parity, even parity or odd parity or 7 bit with even or odd parity.
5.100
Serial address
Section:
SErI
Display:
Unit Addr
Range:
1
to
127
Default Value:
1
Default Access Level
4
Function number
0430
Allows selection of the unit address when the operation is set for
POLL
mode. The unit address is offset by
32(DECIMAL) to avoid clashing with ACSII special characters, therefore 42 (DECIMAL) or 2A (HEX) would be
unit address 10.
5.101
Front P button operation mode
Section:
R.INP
Display:
P.but
Range:
NONE
,
P.Hi
,
P.Lo
,
Hi.Lo
,
AL.Ac
Default Value:
NONE
Default Access Level
4
Function number
4720
Sets the operation mode for front
P
button. Functions available are identical to the same functions used in the
R.IN.1
function.
5.102
Remote input 1 operation mode
Section:
R.INP
Display:
R.IN.1
Range:
NONE
,
P.HId
,
d.HId
,
P.Hi
,
P.Lo
,
Hi.Lo
,
AL.Ac
,
ACCS
,
P.but
,
F.but
,
U.but
,
d.but
,
duII
,
b.Inc
,
b.dEc
Default Value:
NONE
Default Access Level
4
Function number
4721
Sets the operation mode for remote input 1 terminal at the rear of the instrument. Choices are as follows:
62 of