MG3 Hot Bar
How to …?
76609576EN-MG3-HB-V1_0a.docx 35/49
Copy
a
channel
Copy the settings of channel 1 to channel 2 (1
2) or vice versa (2
1) of
the currently active program by clicking the respective button.
PROGRAM NAME
Set a program name for each channel of the currently active program.
5.9
Count Measurements
Here you can make adjustments for the welding counter for channel 1 and 2.
When the set prewarn value is reached, a signal is set at the corresponding
output.
When the end value (counting dir) or zero (counting direction -) is
reached, a signal is set at the corresponding output.
Go to screen COUNTER via MENU – COUNTER.
ON/OFF
Enables/disables the counter for the respective channel.
MODE
Choose the counting direction:
Plus (+) counts forward, starting from zero to set END VALUE.
Minus (-) counts backward, starting from set START VALUE.
END VALUE
End value for the plus counter.
START VALUE
Start value for the minus counter.
PREWARN
Prewarn value of active counter.
RESET
Reset the counter.