MG3 Hot Bar
Commissioning
76609576EN-MG3-HB-V1_0a.docx 13/49
3.1.2.3
Connector X38 (I/O Outputs)
Pin Name
Chan. Function
3
4
Displacement min.
Displacement max.
1
1
High: currently measured displacement
is outside the set limits
5
6
Displacement min.
Displacement max.
2
2
High: currently measured displacement
is outside the set limits
7
8
Prewarn Dist. S3
Prewarn Dist. S6
1
2
High: prewarn value is exceeded
9
10
Sinking 2 Accept 2
Sinking 1 Accept 1
2
1
Output enabled if sinking 2/1 is ACCEPT
11 Pressure/Force
reject
1
12 Pressure/Force
accept
1
13 Pressure/Force
reject
2
14 Pressure/Force
accept
2
17
31
Path Abort
Temperature High
Path Abort
Temperature Low
2
2
High: cutoff value is exceeded.
Low: cutoff value is exceeded.
18,
21
Plus terminal (+)
Common plus terminal (+) for PIN:
14, 13, 11, 12, 10, 9, 8, 7, 6, 5, 4, 3,
30, 29, 28, 27, 26, 25, 24, 23
19 Common (+) 1
1
Common plus terminal 10 – 30 V for PIN
16 and 20.
20
16
Path Abort
Temperature High
Path Abort
Temperature Low
1
1
High: cutoff value is exceeded.
Low: cutoff value is exceeded.
25
26
Parts Detection
Low active
Parts Detection
Low active
1
2
Low: limit values are not reached or
exceeded, (pressure switch control unit).
27
28
Path Parts
Detection min.
Path Parts
Detection max.
1
1
Depending on setup default; becomes
active if the currently measured parts
control path min./max. is exceeded or
remains under.
29
30
Path Parts
Detection min.
Path Parts
Detection max.
2
2
High: currently measured parts detection
path min/max is exceeded or remains
under.
34 Common (+)
2
Common plus terminal 10 – 30 V for PIN
17 and 34.