MG3 Hot Bar
How to …?
76609576EN-MG3-HB-V1_0a.docx 27/49
5.4
Configure the Display Windows (Quadrants)
The measured values can be displayed in four configurable display windows
(quadrants).
Each quadrant can be operated in four different display modes.
Go to screen
VIEW
via MENU - VIEW.
QUADRANT
Select the quadrant 1…4 to be configured.
Each quadrant can show only one measured variable.
CHANNEL
Select the channel for this quadrant.
MODE
Select how the measured variable shall be displayed in this quadrant:
numeric
graphic
(here you can also select the color of the graphs)
SPC*-Chart
SPC*-Values
SPC:
S
tatistical
P
rocess
C
ontrol
Select the measured variable for this quadrant:
HEAT TIME:
Th
TEMPERATURE 1,
TEMPERATURE 2:
Txpk
(peak)
Txavg
(average)
Txt
(integral)
DERIVATIVES:
T1’
(gradient)
T2’
(gradient)
Tdiff
(difference between
T1 and T2)
DISTANCE:
Only during active displacement and/or part detection
(see
chap.
5.5)
Channel
1:
s1
= Part detection
s2
= Switch off value
s3
= Displacement value
Channel 2:
s4
= Part detection
s5
= Switch off value
s6
= Displacement value
FORCE/PRESSURE: Only if active