MG3 Hot Bar
Commissioning
76609576EN-MG3-HB-V1_0a.docx 15/49
3.1.2.6
Connector X60 and X61 (CANopen)
Connection with standard RS232 extension cable (1:1)
Pin
Name
Function
1
Free
2
CAN
_L
Low-level
3
CAN
_GND Ground
4
Free
5
CAN
_SHLD Circuit shield
6
Free
7
CAN
_H
High-level
8
9
CAN-Baud rates
1 MB/s; 800 kB/s; 500 kB/s; 250 kB/s; 125 kB/s;
50 kB/s; 20 kB/s; 10 kB/s
3.1.3
Connecting Temperature Sensor
For the mounting of the thermocouples on the Hot Bar head please see the
operating instructions of the Hot Bar system.
Connect the plug of the thermocouples with the corresponding socket on the
rear side of the MG3 (see chap. 3.1.1).
Note: Switch off the MG3 Hot Bar before connecting
.
3.1.4
Connecting Displacement Sensor (optional)
For displacement measurement you need an optional available displacement
sensor and the corresponding mounting kit.
For the mounting of the displacement sensor on the Hot Bar head please see
the operating instructions of the Hot Bar system.
Connect the plug of the displacement sensor with the supplied sensor cable
adapter and then connect the adapter with the corresponding socket (X31)
on the rear side of the MG3 (see chap. 3.1.1).
Note: Switch off the MG3 Hot Bar before connecting
.
If a WK-adapter is used (necessary for force or pressure measurement),
connect the plug of the displacement sensor directly to the WK-adapter.
3.1.5
Connecting Force or Pressure Sensor (optional)
For force or pressure measurement you need optional available force or
pressure sensor, the corresponding mounting kit and the WK-adapter.
For the mounting of the respective sensor on the Hot Bar head please see the
operating instructions of the Hot Bar system.
Connect the plug of the sensor to the WK-adapter and then connect the
adapter with the corresponding socket (X31) on the rear side of the MG3 (see
chap. 3.1.1).
Note: Switch off the MG3 Hot Bar before connecting
.