MG3 Hot Bar
Commissioning
76609576EN-MG3-HB-V1_0a.docx 16/49
3.1.6
WK-Adapter (optional)
Fig. 3: WK-Adapter
For force or pressure measurement you need an optional available force or
pressure sensor, the corresponding mounting kit and the WK-adapter.
For the mounting of the respective sensor on the Hot Bar head please see the
operating instructions of the Hot Bar system.
Connect the plug of the sensor to the WK-adapter and then connect the
adapter with the corresponding socket (X31) on the rear side of the MG3 (see
chap. 3.1.1).
Note: Switch off the MG3 Hot Bar before connecting
.
3.2
Initial Commissioning
3.2.1
Preconditions
•
Check whether the MG3 Hot Bar is switched off. The main switch must be
in position 0.
See chap. 3.1.1.
•
Check mains voltage and frequency at place of installation. See chap. 2.2.
•
Plug in power supply cord to the corresponding connector at the rear of
the MG3 Hot Bar.
•
Check whether the USB stick is plugged in.
3.2.2
Starting-up
Switch on the main switch on the rear side of the MG3 Hot Bar.
After initialization - lasting for approx. 30 seconds - you can configure the
MG3 Hot Bar.