Interface Board -
Control Board
communication error
No signal transfer for more than 5
seconds between the interface board
and the control board.
1. Make sure the oven plug is fully seated in
electrical outlet.
2. Reset the main circuit breaker for the oven.
If error reoccurs, contact Technical Service.
E-108
Cooling fan over
temperature
Chassis bi-metal temperature sensor
over temperature 130°F (54°C).
1. Make sure the cooling fan(s) are operating.
2. Make sure the exhaust vents are clean and
free of debris.
3. Make sure the oven clearances are met.
4. Ambient temperature greater than 105°F
(41°C).
5. Check the door gasket for damage and
proper seal.
E-109
High limit error
Note:
Contact an
authorized
Alto-Shaam service
partner.
Open circuit detected across high limit
switch.
1. If the oven has experienced an over
temperature condition, allow the oven to cool
down for a minimum of 30 minutes.
2. Press the high limit reset buttons.
3. Continue operation of the oven. If the error
reoccurs, contact Technical Service.
E-606
Oven cleaning system
failure
Convection fan error, high limit error,
cavity temperature sensor open or short,
or communication for at least 15
seconds during cleaning.
1. Contact Technical Service.
2. Manually clean the oven.
3. Manually rinse the oven.
4. Make sure to remove cleaners before
operating the oven.