O
PERATION
Converge®
▪
Operator’s Manual
▪
MN-47238
▪
Rev 1
▪
8/22
84
Continued from previous page
4.
Scroll
c
until “Probe Offsets” displays.
Touch
the “Calibrate Probes”
d
setting.
5.
Compare
the probe temperature reading against 32°F (0°C).
Touch
the “+” or “–” symbols until the temperature displayed is
32°F (0°C)
e
.
Touch
the check mark
f
.
6.
Remove
the probe from the ice water.
7.
If the oven has multiple probes, repeat this procedure until all probes are
calibrated.
Result
The probe is now calibrated.
CT-TS-014920
c
d
XX°
XX°
CT-TS-014923
f
e