![Altendorf WA 6 Operating Manual Download Page 34](http://html1.mh-extra.com/html/altendorf/wa-6/wa-6_operating-manual_2910756034.webp)
Installation
34
Installation
0000010064-007- GB
6.3.5
Cross slide and crosscut-mitre fence
6.3.6
Sliding table
•
Place the bottom carriage on the machine frame and use a special wrench
to tighten the outer fastening screws Push against the stop screws prior to
tightening.
•
Place the middle carriage on the bottom carriage so that the interlock is
pointing to the right.
•
Push the middle carriage up to the stop.
•
Carefully
push the top carriage onto this set-up. Ensure that the sliding
table does not jam and the guide rods are carefully pushed onto the double
rollers.
•
Push the top carriage towards the left, all the way to the stop.
•
Fit the back stop. Check whether the stop on the top carriage and the stop
on the bottom carriage hit the end position at the same time and re-align, if
necessary.
•
Prior to start up, check the setting of the sub-rollers.
•
Position the supporting pipe (1) of the cross slide (2) on
the bolt (3) of the telescopic tube (4)
•
Attach the cross slide to any point of the sliding table (5)
and use the eccentric lever (6) to clamp it
•
Position the crosscut-mitre fence (7) on the cross slide
•
Attach and tighten all clamping screws (8)
Summary of Contents for WA 6
Page 7: ...Machine identification 7 0000010064 007 GB Machine identification...
Page 11: ...Identification 11 0000010064 007 GB Identification EC prototype testing certificate...
Page 12: ...Identification 12 Identification 0000010064 007 GB DGUV Test Certificate...
Page 13: ...Identification 13 0000010064 007 GB Identification Certificate renewal...
Page 14: ...Identification 14 Identification 0000010064 007 GB C US certificate...
Page 75: ...Maintenance and repairs 75 0000010064 007 GB Maintenance and repairs...
Page 76: ...Maintenance and repairs 76 Maintenance and repairs 0000010064 007 GB...