Altec AIR CO2-PG14 CO2-Free Gas Generator Operations and Maintenance Manual

 

Page 8

 

P012548-14 - Rev D 

PROBLEM: RESTRICTED FLOW THROUGH UNIT 

  

  

POSSIBLE CAUSE 

CHECK 

CORRECTIVE ACTION 

B1 

Improper operating 
conditions. 

See A3 above. 

  

B2 

Dirty or obstructed inlet air 
filter. 

See A4 above. 

  

B3 

Plugged air passages. 

Check inlet and outlet air passages and 
piping for blockages. 

Clear restrictions. 

 

PROBLEM: EXCESSIVE PURGE 

  

  

POSSIBLE CAUSE 

CHECK 

CORRECTIVE ACTION 

C1 

Inlet valve or outlet shuttle 
not shifting. 

Check for damage or contamination of 
inlet valve and outlet shuttle valve. 

Clean or replace as necessary. 

C2 

Timer not operating properly. 

Incoming power may not be "clean".  
Fluctuations in voltage can occur in power 
circuits shared by inductive devices such 
as electric motors or welders. 

Supply line voltage from another source or 
install power line filter. 

Summary of Contents for CO2-PG14

Page 1: ...allation Safety Operation Safety SECTION 3 Specifications Pg 3 Flows Connections Dimensions and Weights SECTION 4 Installation Pg 4 Parts Included Location Electrical Connections Piping and Connection...

Page 2: ...this tower removes CO2 to less than 1 ppm and 99 9 of the water vapor from the air when operated at standard catalog conditions The dry CO2 free air leaving the top of the tower T1 is directed to the...

Page 3: ...de pressurize the unit before starting installation or maintenance procedures The CO2 PG14 is rated NEMA 1 2 2 OPERATION SAFETY DO NOT OPERATE THE PURGE GAS GENERATOR AT COMPRESSED AIR PRESSURES ABOVE...

Page 4: ...T IN AN ENVIRONMENT OF CORROSIVE CHEMICALS EXPLOSIVE GASES OR AREAS OF HIGH AMBIENT TEMPERATURE CONDITIONS 4 3 ELECTRICAL CONNECTIONS Before plugging in unit check the unit nameplate for electrical ch...

Page 5: ...ER DRYER IS DEPRESSURIZED BEFORE WORKING ON THE ADSORBER DRYER OR RELATED EQUIPMENT ENSURE THAT ALL PERSONNEL HAVE READ AND UNDERSTAND THE SAFETY AND OPERATION INSTRUCTIONS IN THIS MANUAL 6 1 PREVENTI...

Page 6: ...ee Sec 6 1 OUTLET FILTER REGULATOR WITH GAUGE 1 1 1 1 See Sec 6 1 OUTLET FILTER ELEMENT ONLY 1 1 1 1 See Sec 6 1 REGULATOR ONLY 1 1 1 1 50027 TIMER CYCLE 115 VAC 1 50029 TIMER CYCLE 220 VAC 1 51408 TI...

Page 7: ...ed outlet flow Reduce air usage downstream A4 Dirty or obstructed inlet air filter Check inlet coalescing filter element Replace inlet filter element A5 Purge orifice plugged Check purge air flow with...

Page 8: ...t air passages and piping for blockages Clear restrictions C PROBLEM EXCESSIVE PURGE POSSIBLE CAUSE CHECK CORRECTIVE ACTION C1 Inlet valve or outlet shuttle not shifting Check for damage or contaminat...

Page 9: ...be repaired replaced or refunded at Altec AIR s option free of charge provided that Altec AIR is notified within the above stated warranty period All returns of defective parts equipment must have pr...

Reviews: