Altec AIR CO2-PG14 Operation & Maintenance Manual Download Page 5

Altec AIR CO2-PG14 CO2-Free Gas Generator Operations and Maintenance Manual

 

Page 5

 

P012548-14 - Rev D 

adsorbent  media  dust  that  may  migrate  from  the  desiccant 
beds. 

 
 

SECTION 5  START UP 

 
BEFORE UNIT START UP, FOLLOW THE INSTALLATION 
INSTRUCTIONS AND PROCEDURES COMPLETELY. 
 
DO NOT REMOVE, REPAIR OR REPLACE ANY ITEM ON 
THE ADSORBER/DRYER WHILE THE ADSORBER/DRYER 
IS UNDER PRESSURE. 
 

5.1 

INITIAL START UPS 

 
1. 

Confirm that all piping and electrical connections are 
proper. 

2. 

Turn on the electrical power. Adsorber/dryer should start 
cycling with a small purge noise heard every 30 seconds. 

 
SECTION 6  MAINTENANCE  

 
DO  NOT  REMOVE,  REPAIR,  OR  REPLACE  ANY  ITEM  ON 
THE  ADSORBER/DRYER  WHILE  THE  ADSORBER/DRYER 
IS UNDER PRESSURE. 
 
BEFORE  BEGINNING  ANY  REPAIRS,  MAINTENANCE,  OR 
INSTALLATION  WORK,  VERIFY  THAT  THE  POWER  IS  OFF 
AND THE ADSORBER/DRYER IS DEPRESSURIZED. 
 
BEFORE  WORKING  ON  THE  ADSORBER/DRYER  OR 
RELATED  EQUIPMENT,  ENSURE  THAT  ALL  PERSONNEL 
HAVE  READ  AND  UNDERSTAND  THE  SAFETY  AND 
OPERATION INSTRUCTIONS IN THIS MANUAL. 
 

6.1 

PREVENTIVE MAINTENANCE  

 

Below  is  a  suggested  schedule  based  on  average  operating 
conditions.    As  conditions  such  as  dirty  environment,  humidity 
conditions, ambient temperature, etc. change, the frequency of 
the inspections may need to be increased. 
 
Daily 

 

1. 

Inspect the adsorber/dryer for proper cycling. 

2. 

Inspect inlet filters for proper operation. 

3. 

Verify proper inlet and ambient air conditions. 

 
Semi-Annually 
 
1. 

Inspect  entire  assembly  for  loose  connections,  screws, 
etc. 

 
Annually 
 
1. 

Replace  inlet  filter  elements,  outlet  filter  elements,  and 
purge muffler [see next page for correct type]: 

 

Inlet Filter  

Element  

Type A: # M03-02-D00 
Type B: # AC-0015XA 

Type A: # PS446 
Type B: # E00060015XA 

Outlet Filter/Regulator 

Element  

Type A: # B03-03-G000 
Type B: # AP-0015X1 
Type B: # P017358 

(NIPPLE-

P5000107)

 

Type A: # PS403 
Type B: # E00060015X1 

Purge Muffler 

# 10040 

 

Summary of Contents for CO2-PG14

Page 1: ...allation Safety Operation Safety SECTION 3 Specifications Pg 3 Flows Connections Dimensions and Weights SECTION 4 Installation Pg 4 Parts Included Location Electrical Connections Piping and Connection...

Page 2: ...this tower removes CO2 to less than 1 ppm and 99 9 of the water vapor from the air when operated at standard catalog conditions The dry CO2 free air leaving the top of the tower T1 is directed to the...

Page 3: ...de pressurize the unit before starting installation or maintenance procedures The CO2 PG14 is rated NEMA 1 2 2 OPERATION SAFETY DO NOT OPERATE THE PURGE GAS GENERATOR AT COMPRESSED AIR PRESSURES ABOVE...

Page 4: ...T IN AN ENVIRONMENT OF CORROSIVE CHEMICALS EXPLOSIVE GASES OR AREAS OF HIGH AMBIENT TEMPERATURE CONDITIONS 4 3 ELECTRICAL CONNECTIONS Before plugging in unit check the unit nameplate for electrical ch...

Page 5: ...ER DRYER IS DEPRESSURIZED BEFORE WORKING ON THE ADSORBER DRYER OR RELATED EQUIPMENT ENSURE THAT ALL PERSONNEL HAVE READ AND UNDERSTAND THE SAFETY AND OPERATION INSTRUCTIONS IN THIS MANUAL 6 1 PREVENTI...

Page 6: ...ee Sec 6 1 OUTLET FILTER REGULATOR WITH GAUGE 1 1 1 1 See Sec 6 1 OUTLET FILTER ELEMENT ONLY 1 1 1 1 See Sec 6 1 REGULATOR ONLY 1 1 1 1 50027 TIMER CYCLE 115 VAC 1 50029 TIMER CYCLE 220 VAC 1 51408 TI...

Page 7: ...ed outlet flow Reduce air usage downstream A4 Dirty or obstructed inlet air filter Check inlet coalescing filter element Replace inlet filter element A5 Purge orifice plugged Check purge air flow with...

Page 8: ...t air passages and piping for blockages Clear restrictions C PROBLEM EXCESSIVE PURGE POSSIBLE CAUSE CHECK CORRECTIVE ACTION C1 Inlet valve or outlet shuttle not shifting Check for damage or contaminat...

Page 9: ...be repaired replaced or refunded at Altec AIR s option free of charge provided that Altec AIR is notified within the above stated warranty period All returns of defective parts equipment must have pr...

Reviews: