Altec AIR CO2-PG14 Operation & Maintenance Manual Download Page 6

Altec AIR CO2-PG14 CO2-Free Gas Generator Operations and Maintenance Manual

 

Page 6

 

P012548-14 - Rev D 

 

 

Type A

 

Type B

 

 

Filter Comparison to determine correct Replacement Part #’s

 

 

 
SECTION 7  REPLACEMENT PARTS  

 

 

Part Number 

Description 

CO2-PG14 

(115V) 

CO2-PG14-2 

(230V) 

CO2-PG14-

12VDC 

CO2-PG14-

24VDC 

51460 

PURGE ORIFICE, .015 WITH TUBING 

51802 

SHUTTLE VALVE ASSY 

See Sec. 6.1  OUTLET FILTER/REGULATOR WITH GAUGE 

See Sec. 6.1 

- OUTLET FILTER ELEMENT ONLY 

See Sec. 6.1 

- REGULATOR ONLY 

50027 

TIMER, CYCLE, 115 VAC 

 

 

 

50029 

TIMER, CYCLE, 220 VAC 

 

 

 

51408 

TIMER, CYCLE, 12 VDC 

 

 

 

P012759 

TIMER, CYCLE, 24 VDC 

 

 

 

10040 

MUFFLER, PURGE, 1/8 NPT 

51441 

SOLENOID VALVE ASSY, 115 VAC 

 

 

 

51441-2 

SOLENOID VALVE ASSY, 220 VAC 

 

 

 

51441-12VDC  SOLENOID VALVE ASSY, 12 VDC 

 

 

 

51441-24VDC  SOLENOID VALVE ASSY, 24 VDC 

 

 

 

See Sec. 6.1  INLET FILTER WITH AUTO DRAIN 

See Sec. 6.1 

- INLET FILTER ELEMENT ONLY 

 
 
 

Inlet Filter 

Outlet Filter 

Summary of Contents for CO2-PG14

Page 1: ...allation Safety Operation Safety SECTION 3 Specifications Pg 3 Flows Connections Dimensions and Weights SECTION 4 Installation Pg 4 Parts Included Location Electrical Connections Piping and Connection...

Page 2: ...this tower removes CO2 to less than 1 ppm and 99 9 of the water vapor from the air when operated at standard catalog conditions The dry CO2 free air leaving the top of the tower T1 is directed to the...

Page 3: ...de pressurize the unit before starting installation or maintenance procedures The CO2 PG14 is rated NEMA 1 2 2 OPERATION SAFETY DO NOT OPERATE THE PURGE GAS GENERATOR AT COMPRESSED AIR PRESSURES ABOVE...

Page 4: ...T IN AN ENVIRONMENT OF CORROSIVE CHEMICALS EXPLOSIVE GASES OR AREAS OF HIGH AMBIENT TEMPERATURE CONDITIONS 4 3 ELECTRICAL CONNECTIONS Before plugging in unit check the unit nameplate for electrical ch...

Page 5: ...ER DRYER IS DEPRESSURIZED BEFORE WORKING ON THE ADSORBER DRYER OR RELATED EQUIPMENT ENSURE THAT ALL PERSONNEL HAVE READ AND UNDERSTAND THE SAFETY AND OPERATION INSTRUCTIONS IN THIS MANUAL 6 1 PREVENTI...

Page 6: ...ee Sec 6 1 OUTLET FILTER REGULATOR WITH GAUGE 1 1 1 1 See Sec 6 1 OUTLET FILTER ELEMENT ONLY 1 1 1 1 See Sec 6 1 REGULATOR ONLY 1 1 1 1 50027 TIMER CYCLE 115 VAC 1 50029 TIMER CYCLE 220 VAC 1 51408 TI...

Page 7: ...ed outlet flow Reduce air usage downstream A4 Dirty or obstructed inlet air filter Check inlet coalescing filter element Replace inlet filter element A5 Purge orifice plugged Check purge air flow with...

Page 8: ...t air passages and piping for blockages Clear restrictions C PROBLEM EXCESSIVE PURGE POSSIBLE CAUSE CHECK CORRECTIVE ACTION C1 Inlet valve or outlet shuttle not shifting Check for damage or contaminat...

Page 9: ...be repaired replaced or refunded at Altec AIR s option free of charge provided that Altec AIR is notified within the above stated warranty period All returns of defective parts equipment must have pr...