DLM-600 installer & user manual Rev. 1.3
16-11-2011
32 / 39
NOTE:
the last action (Disconnect) can also be done automatically. For this option select the 'Auto
Disconnect’ option from the Options toolbar. If this option is not selected, the button next to the
Program
Flash
button
Disconnect
is shown, if the option is selected, the button Disconnect is not shown.
S
TARTING UP AFTER FLASHING
Follow the instructions below closely to successfully start up the DLM-600 after flashing:
o
Disconnect the power supply from the DLM-600
o
Remove the serial cable between the PC and the DLM-600
o
Place the jumpers J43 and J44 back to the 'run' mode. For J43 the two left pins must be
connected and for J44 the two right pins should be connected.
o
Remove the jumper from J40 (PRG)
Reapply the power to the DLM-600. The green watchdog LED (below J40) will now illuminate. This is the
indication that the DLM-600 uses the new firmware correctly.