Legend hydraulic diagramm

140304

1

Heat pump

51

Seperation tank

TA/

A

External sensor

2

Underfloor heating / radiators

52

Gas- or oil-boiler

TBW/B

Domestic hot water sensor

3

Vibration isolation

53

Wood boiler

TB1/C

Feedwater sensor mixer circuits 1

4

Sylomer strip machine underlay

54

Hot water cylinder

D

Floor tmperature limiter

5

Closure and drainage

55

Brine pressure switch

TRL/G

Sensor external return

6

Expansion vessel packing list

56

Swimming pool heat exchanger

ST

A

Line pressure regulator valve

7

Safety valve

57

Geothermal heat exchanger

TRL/H

Sensor return 

(h

ydraulic module, dual

)

8

Closure 

58

Ventilation system

9

Heating circulation pump

59

Plate heat exchanger

79

Motor valve

10

Non return valve/ one way valve

61

Cooling cylinder

80

Mixin

g valve

11

Individual room regulation

65

Compact distributor

81

Sp

lit heat 

pum

p outdoor unit

12

Overflow valve

66

Fancoils

82

Sp

lit heat 

pum

p indoor unit 

13

Steamtight insulation

67

Solar/ service water cylinder

83

Circulation

pum

p

14

Service water circulation pump

68

Solar/ service water cylinder

84

Switchin

g valve

15

Mixer circuit three-way mixer (MK1 discharge)

69

Multifunction tank

113

Connection 2nd heat generator    

16

Expansion vessel supplied by customer

71

Dual hydraulic module

BT1

Outdoor tem

perature sensor

18

Heating rod (heating)

72

Buffer tank wall mounted

BT2

Flow tem

perature sensor 

19

Mixer circuit four-way mixer (MK1 charge)

73

Pipe lead-in

BT3

Return tem

perature sensor

20

Heating rod (SW)

74

Ventower

BT6

Domestic hot water tem

perature sensor

21

Mixer circuit circulation pump (FP1)

75

Scope of delivery, hydraulic tower, dual

BT12

Flow tem

perature li

quefier

23

Feed circulating pump (reconnect the integrated circulating pump  in the heat pump)

76

Fresh water station

BT19

Temperature sensor immersion heater                 

24

Manifuld

77

Scope of supply water/water booster

BT24

Tem

perature sensor 2nd heat 

generator

25

Heating circulation pump

78

Accessories water/water booster optional

26

 

Sw

itching v

alv

e (heating/serv

ice w

ater)(B

 = normally

 open)

27

Heating element

28

Brine circulation pump

Comfort board:

29

Dirt-trap 0.6 mm mesh

15

Mixer circuit three-wa

y mixer 

(MK2-3 dischar

ge

)

30

Spill-tray für brine mix

100

Room thermostat for cooling (optional)

17

Temperature difference regulator

31

Wall breakthrough

101

Controls supplied by customer

19

Mixer circuit four-way mixer (MK2 charge)

32

Inlet pipe

102

Dew-point monitor (optional)

21

Mixer circuit circulation pump (FP2-3)

33

Brine manifuld

103

Room thermostat for reference space in packing list

22

Swimming pool circulating pump

34

Ground collector

104

Supply heat pump

44

Three-way mixer valve (cooling function MK2)

35

Ground slinkies

105

Cooling circuit module box removeable for installation

47

 

C

hangeov

er v

alv

e sw

imming bath preparation(B

 = normally

 open)

36

Groundwater spring pump

106

Specific glycole mixture

60

C

hangeov

er v

alv

e cooling operation(B

 = normally

 open)

37

Wall bracket

107

Scald protection / thermostatic mixer valve

62

Heat meter (optional)

38

Flow switch

108

Solar pump assembly

63

C

hangeov

er v

alv

e solar circuit(B

 = normally

 open)

39

Suction well

109

Overflow valve must be closed

64

Cooling circulation pump

40

Inverted well

110

Packing list hydraulic tower

70

Solar seperation module

41

Rinse fitting heating circuit

111

Mounting for additional heating element

TB2-3/C

Feedwater sensor mixer circuits 2-3

42

Circulation pump

112

Minimum distance to thermal decoupling of the mixing valve

TSS/E

Sensor, temperature difference control (low

 temperature)

43

Brine / Water heat exchanger (cooling function)

TSK/E

Sensor, temperature difference control (high temperature)

44

Three-way mixer valve (cooling function MK1)

TEE/F

Sensor external energy source

45

Cap valve

46

Filler and drainage valve

48

Domestic hot water charging pump

49

Direction of groundwater flow

50

Buffer storage

Important notice !

These hydraulic diagrams are schematic representations and are for assistance only. They do not relieve of the obligation to ca

rry out appropriate planning! They do not include all necessary shut-off valves, ventilator 

fittings or safety devices. These must be incorporated in accordance with the standards and regulations applicable to the respe

ctive installation. All country-specific standards, laws and regulations must be observed! The 

tubes have to be dimensioned according to the nominal volume flow of the heat pump resp. the free pressing of the integrated ci

rculating pump. For detailed information and advice please contact our local sales partner!

Summary of Contents for LWP 450-LUX

Page 1: ...UK 83059700iUK Translation of the original operating manual Air water heat pumps Operating Manual LWP...

Page 2: ...installation 11 8 Flushing filling and venting 12 8 1 Heating water quality 12 8 2 Flushing filling and venting the heating circuit 12 9 Insulate hydraulic connections 13 10 Set the overflow valve 13...

Page 3: ...draulic integration Operating manual of the heating and heat pump controller Brief description of the heat pump controller Operating manual of the expansion board Log book 1 3 Symbols and markings Ide...

Page 4: ...uries and damage to property Ensure that personnel are familiar with local regulations especially those on safe and hazard aware working Allow qualified personnel with electrical training only to carr...

Page 5: ...stems Proper planning design and commissioning Closed system with regard to corrosion Integration of an adequately dimensioned pressure maintaining device Use of demineralised heating water or VDI 203...

Page 6: ...ipes Transport with a crane page 9 2 Cut outs for transport with a forklift ATTENTION Only transport the unit to the installation location in its original packaging 3 2 Layout NOTE This section essent...

Page 7: ...is used in the heating circuit The liquid refrigerant at a high pressure and high temperature is depressurised expansion valve The pressure and temperature drop and the process begins again The heate...

Page 8: ...There is a risk of cutting your hands on sharp edges of the device Wear cut resistant protective gloves The hydraulic connections are not designed for mechanical loads Do not lift or transport the dev...

Page 9: ...packaged Unpacking 1 Remove plastic films Ensure that you do not damage the device 2 Dispose of the transport and packaging material in an environmentally friendly way and in accordance with local reg...

Page 10: ...e adequately dimensioned The connection line between the heat pump and the building must also be taken into account 9 9 Dimension the recirculating pump and piping system such that the required throug...

Page 11: ...the ground to a depth of at least 90 cm If the condensate is discharged into the sewer system ensure frost free laying with a gradient Discharge of the condensate into the sewers is permitted only via...

Page 12: ...the heat pump 8 Flushing filling and venting 8 1 Heating water quality NOTE For detailed information refer among other things to the VDI Guidelines 2035 Vermeidung von Sch den in Warmwasserheizanlage...

Page 13: ...necessary for the integration of storage tanks in series Complete the work steps quickly otherwise the maximum return temperature may be exceeded and the heat pump switches to high pressure fault Turn...

Page 14: ...e manufacturer s factory customer service department In other countries Send notice of completion for heat pump systems and rough checklist to the manufacturer s local partner 4 Arrange for the heat p...

Page 15: ...ing product Neutralise any residues and flush the condenser thoroughly with water 12 4 Yearly maintenance Record the quality of the heating water analytically In case of deviations from the specificat...

Page 16: ...16 Subject to technical amendments without notice 83059700iUK Translation of the original operating manual ait deutschland GmbH...

Page 17: ...h Hot gas use Flow rate pipe dimensioning l h 2000 Free pressing Pressure loss Flow rate bar bar l h 0 952 0 045 2000 General unit data Total weight kg 680 Weight of individual components kg kg kg Ref...

Page 18: ...ungszahl maximale freie Pressung W rmepumpe 10 15 20 25 30 35 40 45 50 55 60 65 70 75 22 17 12 7 2 3 8 13 18 23 28 33 Temp C Qh kW 35 C 1VD 55 C 1VD 35 C 2VD 55 C 2VD 1 2 3 4 5 6 22 17 12 7 2 3 8 13 1...

Page 19: ...9 2017 VD R cklauf 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 15 20 25 30 35 40 Temp C Q0 kW 7 C 1VD 18 C 1VD 10 C 2VD 18 C 2VD 1 2 3 4 5 6 15 20 25 3...

Page 20: ...3 0 3 5 GH m h p bar p1 0 5 10 15 20 25 30 35 40 45 50 55 60 25 30 35 40 45 50 55 60 65 Q hg TempHG C Hz A7 35 C 1VD 55 C 1VD 0 5 10 15 20 25 30 35 40 45 50 55 60 25 30 35 40 45 50 55 60 65 Q hg TempH...

Page 21: ...21 Subject to technical amendments without notice 83059700iUK Translation of the original operating manual ait deutschland GmbH...

Page 22: ...212 197 362 327 0 135 245 335 195 Z 1 10 FB 1 0 132 497 682 928 778 0 160 296 475 Y 1 10 7 6 9 8 6 5 4 3 2 1 www ait deutschland D 95359 Kasend Industriestra e 3 ait deutschland Gm A B C D E F 4 3 2...

Page 23: ...17 M 034 2019 Kondensatablauf Datum 25 10 1 11 07 1 05 04 1 Blattformat A3 quer Installation plan base plan LWP Pos Name 1 Hot water outlet supply flow DN 50 insulation 2 Hot water inlet return flow D...

Page 24: ...K Translation of the original operating manual ait deutschland GmbH 1000 4000 4000 1000 4000 Mindestabst nde in mm zu Geb uden oder W rmepumpen 4 3 2 1 A B C D E F 4 3 2 1 b a Zust a b Minimum clearan...

Page 25: ...3400 4000 4000 1800 1000 1800 1000 1800 1000 1800 850 12200 8850 1000 1000 4000 4000 luftseitig bevorzugte Aufstellvariante Kaskadenaufstellung 4 Ger te Mindestabst nde in mm zu Geb uden 4 3 2 1 A B C...

Page 26: ...at the condensed water is routed in such a way as to be protected from frost 0 9m KS 3 0 9m 3 3 Legende 819492b Technische nderungen vorbehalten Aufstellungshinweise f r Anschluss der Kondensatleitung...

Page 27: ...t the condensate is discharged frost free in all cases figure 2a 2a 2b Legende 819492b Technische nerungen vorbehalten Aufstellungshinweise f r Anschluss der Kondensatleitung innerhalb des Geb udes Wi...

Page 28: ...bH LWP with multifunction tank as domestic hot water tank Heating 3 3 31 31 5 5 7 24 16 104 A TA A B A B 26 BUP 51 G TRL 2 2 11 11 8 8 8 8 10 10 8 8 STA D 15 9 HUP 21 FP1 MK1 C TB1 16 B TBW 111 TEH 8...

Page 29: ...5 5 7 24 16 8 8 10 Ent 2 11 8 8 10 8 D 15 21 FP1 MK1 C TB1 16 C TB2 T 103 T 102 60 FP3 60 FP3 66 11 8 8 10 8 9 HUP T 102 AB A B A B B A 8 5 10 23 ZUP 8 10 23 ZUP 5 8 10 64 FP2 AB B A 60 FP2 20 ZWE 1 B...

Page 30: ...rt trap 0 6 mm mesh 15 Mixer circuit three way mixer MK2 3 discharge 30 Spill tray f r brine mix 100 Room thermostat for cooling optional 17 Temperature difference regulator 31 Wall breakthrough 101 C...

Page 31: ...closed Charge discharge cooling mixer 1 open Auxiliary circulation pump Diverting valve for domestic hot water Heating circuit circulating pump Pump for mixing circuit 1 Energy supplier contact closed...

Page 32: ...stallation Hot water or buffer storage tank Cut out auxiliary heating Contactor for auxiliary heating Control signal of additional heat generator 1 831224a 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E...

Page 33: ...230V 5A floating contact GND MA2 MZ2 Swimming pool thermostat FP3 analogue output 2 0 10V TFB2 Pump mixing circuit 2 dry contact ZW3 AIN 21 AIN 21 OUT 24 NTC 25 MZ3 A0 22 Sensor mixing circuit 3 AIN...

Page 34: ...jection Compressor 2 817422c Q1 1 E1 0 R20 Q2 0 Q2 1 Q2 2 3 M2 Y2 0 Q2 1 E2 0 R21 X7 Q0 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 1 4 3 4 5 6 7 AIT 817422 Stromlaufplan ait deutschland Gm...

Page 35: ...ction fan 817422c Q3 0 3 M3 E3 0 K1 0 3 M4 B1 E4 0 K2 0 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 2 4 3 4 5 6 7 AIT 817422 Stromlaufplan ait deutschland GmbH M999 2018 M999 2018 M999 2018...

Page 36: ...ressor 1 Terminal in switch box heat pump 817422c Q1 1 K1 0 Q2 1 K21 K2 0 K22 K20 X10 XM 1 M5 C5 X4 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 3 4 3 4 5 6 7 AIT 817422 Stromlaufplan ait de...

Page 37: ...sensor 20 5kOhm 20 5kOhm R3 817422c R4 Encoding resistor Encoding resistor R5 R6 R7 R8 R10 B10 X8 B11 X20 X11 X3 X2 X1 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 4 4 3 4 5 6 7 AIT 817422...

Page 38: ...38 Subject to technical amendments without notice 83059700iUK Translation of the original operating manual ait deutschland GmbH...

Page 39: ...N 60335 1 2 40 EN ISO 13857 EN 61000 3 2 3 3 EN ISO 12100 1 2 EN 55014 1 2 Company Place date Signature Designated position T V S D Industrie Service GmbH Nr 0036 EC Directives 2014 68 EU Designation...

Page 40: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf Germany www ait deutschland eu alpha innotec an ait deutschland GmbH brand UK...

Reviews: