Subject to technical amendments without notice | 83059700iUK – Translation of the original operating manual | ait-deutschland GmbH
●
Check at regular intervals whether the evaporator
and the leaf guard need to be cleaned
1 Evaporator (left, right)
2 Leaf guard
1. Unscrew both top sidewalls for best possible
access.
2. If necessary remove leaves and contaminants.
3. Reattach sidewalls.
●
Check regularly to ensure that the condensate
can drain out of the unit freely, without obstruction.
To this end, check the condensate pan in the unit
and the evaporator regularly for dirt / blockages
and clean as necessary
12.3
Clean and flush condenser
1.
Clean and flush the condenser in accordance with
the manufacturer's instructions.
2.
After flushing the condenser with chemical clean
-
ing product: Neutralise any residues and flush the
condenser thoroughly with water.
12.4 Yearly maintenance
►
Record the quality of the heating water analytically.
In case of deviations from the specifications, take
suitable measures without delay.
13 Faults
1. Read out the cause of the fault via the diagnostics
program of the heating and heat pump controller.
2. Contact the local partner of the manufacturer or
the factory's customer service. Have the fault
message and unit number to hand.
14 Dismantling and disposal
14.1 Dismantling
The device is safely disconnected from the power
supply and protected against being switched back
on again.
►
Collect all media safely.
►
Separate components by their materials.
14.2 Disposal and recycling
►
Dispose of environmentally hazardous media
in accordance with local regulations (e. g.
refrigerant, compressor oil)
►
Recycle or ensure proper disposal of device
components and packaging materials in
accordance with local regulations.