35
Subject to technical amendments without notice | 83059700iUK – Translation of the original operating manual | ait-deutschland GmbH
LW450-600A
a
b
c
Legend:
Equipement
3~PE/400V/50Hz
B1
K1.0
K2.0
M
3
M
4
Q3.0
VENT1
VENT2
UK
Function
L1,L2,L3,PE; power supply, output, compressor; clockwise rotary
field is absolutely necessary!
Phase sequence relay; if phase sequence in the order of 11 + 14
is closed
Auxiliary relay, fan activation
Auxiliary relay, fan activation
Fan
Fan
Motor protection fan
817422c
-Q3.0
3~
-M3
-E3.0
-K1.0
3~
-M4
-B1
-E4.0
-K2.0
1
2
3
4
5
6
7
8
1
2
8
A
B
C
D
E
F
A
B
C
D
E
F
Blatt
Bl.
2
4
3
4
5
6
7
AIT
817422
Stromlaufplan
ait-deutschland GmbH
ÄM999/2018
ÄM999/2018
ÄM999/2018
11.07.2018
13.06.2017
20.11.2018
AP
AP
AP
L1
/1.A8
L2
/1.A8
L3
/1.A8
PE.
/1.C8
2
1
3
4
5
6
13
14
21
22
I>>
I>>
I>>
L1
L2
VENT1
L3
PE
E1
GND
24V
D1
+13
14
M3 E1
/4.B7
M3 GND
/4.B7
L1
L2
VENT2
L3
PE
E1
GND
24V
D1
ASD
/3.C1
L Reg
/3.A1
L E3.0
/3.D1
N E3.0
/3.D1
L E4.0
/3.D1
N E4.0
/3.D1
+13
14
M4 E1
/4.B7
M4 GND
/4.B7
M
M
Änderung
Datum
Datum
Bearbeiter
Geprüft
Norm
Name
31.08.2015
Pfleger
R.
-M3
1
23P
E
4
5
-M3.1
1
2
3
4
-M4
1
L1
L2
L3
11
12
14
23
PE
45
-M4.1
1
2
3
4
LWP
Circuit diagram 2/4