9 - CHANGE PARAMETERS - ADVANCED MENU
This menu allows a more detailed setting of some parameters.
To enter the ADVANCED MENU, press and hold the “MENU” button for at least 5 seconds.
To change the parameters, proceed as described for the BASIC MENU.
WARNING - after 2 minutes of inactivity, the control unit exits automatically from the menu.
PARAMETERS
DESCRIPTION
DEFAULT
CUSTOM
MIN
MAX
UNIT
1
sn
.
m
.
Intervention mode of the current sensor:
0 = disabled.
1 = complete (limit switch and obstacle)
1
2 = only obstacle detection in any point of the stroke.
3 = only end of the movement in any point of the stroke.
1
2
0
3
2
sI
.
t
.
Intervention time of the current sensor.
2
1
10
x 100ms
3
sd
.
t
.
The disabling time of the current sensor during the start of the motor.
15
0
30
x 100ms
4
ur
.
a
.
Acceleration ramp amplitude:
0…20 = ramp amplitude.
SSr
= single step at 50% of the running speed.
2
Hsr
= single step at 100% of the running speed.
2
10
0
20
x 35ms
5
dr
.
a
.
Deceleration ramp amplitude.
10
0
20
x 35ms
6
sp
.
h
.
Functioning of closing photocell (PH1) moving from closed:
0 = check PH1.
1 = the automation opens also with PH1 obscured.
1
0
1
7
ph
.
2
.
Functioning of opening photocell PH2
0 = enabled in opening and closing.
1 = enabled only in opening.
0
0
1
8
tp
.
h
.
Photocells test:
0 = disabled.
1 = enabled PH1.
2 = enabled PH2.
3 = enabled PH1 and PH2.
0
0
3
9
ed
.
m
.
Safety edge type:
0 = contact (NC).
1 = resistive (8k2).
0
0
1
10
ie
.
d
.
Operation mode of safety edge:
0 = working only in closing with inversion of movement.
1 = stops the automation (both opening and closing) and free the obstacle
(short inversion).
0
0
1
11
te
.
d
.
Safety edge test:
0 = disabled.
1 = enabled.
0
0
1
12
LP
.
o
.
Partial opening.
30
0
100
%
13
TP
.
C
.
Auto reclosing time from partial opening (0 = disabled).
0
0
900
s
14
FP
.
R
.
Blinker output mode:
0 = fix.
1 = blinking.
1
0
1
15
TP
.
R
.
Pre-flashing time (0 = disabled).
0
0
10
s
16
FC
.
Y
.
Courtesy ligth settings:
0 = at the end of the movement for a
TC
.
Y
. time.
1 = on if the automation is not
TC
.
Y
. time.
2 = on if the courtesy light timer (
TC
.
Y
.) is not expired.
3 = open automation light on/off.
4 = open automation light with proportional flashing.
0
0
4
17
tC
.
y
.
Courtesy light time.
180
0
900
s
18
de
.
a
.
Dead-man:
0 = disabled.
1 = enabled.
0
0
1
UP
DOWN
MENU
SS
Summary of Contents for BIOS1 24V
Page 1: ...BIOS1 24V MADE IN ITALY CENTRALINA PER CANCELLI SCORREVOLI 24V...
Page 21: ...BIOS1 24V CONTROL UNIT FOR SLIDING GATES AT 24V MADE IN ITALY...
Page 41: ...BIOS1 24V CENTRAL DE COMMANDE POUR PORTAIL COULISSANT 24V MADE IN ITALY...
Page 61: ...BIOS1 24V CUADRO DE MANDO PARA CANCELAS CORREDERAS 24V MADE IN ITALY...
Page 81: ...BIOS1 24V BESTURINGSEENHEID VOOR SCHUIFPOORTEN 24V MADE IN ITALY...
Page 101: ...BIOS1 24V 24V KAYAR KAPILAR N KUMANDA MERKEZ TALYAN MALI...