6/20
6-1622400 rev. 8 19/01/2022
ENG
ITA
ENG
FRA
ESP
NLD
TUR
4.1 - LIST OF TERMINAL BOARDS AND CONNECTORS
Number
Name
Description
1 - 2
FLASH
Flashing light output at 24Vac. Use a flashing light without self flashing card 24Vac 25W max.
3 - 4
OGL
Courtesy light / Open automation light output at 24Vac. Use a light 24Vac 25W max. The
functioning of the auxiliary light and its activation time are managed from advanced items
FC
.
Y
. and
tc
.
y
.
5
+24VDC
+24Vdc accessories power supply. Used for the receiver of the photocells.
6
GND
0Vdc accessories power supply.
WARNING -
The control unit supplies up to a maximum of 200 mA (5W) for the accessories
at 24Vdc.
7
+24VDC TX PHOTO
+24Vdc accessories power supply. Used for the transmitter of the photocells. This connection
is necessary in case of use of the photocells test. It is possible to enable the photocells test
from the advanced menu
tp
.
h
.
8
PE
Ground connection.
9 - 10
EDGE
Safety edge input (NC contact). Select the type of the used safety edge (mechanical or resistive)
through the advanced menu
ED
.
M
. and the mode of intervention with the advanced menu
ie
.
d
.
WARNING -
with DIP EDGE on “ON” the input is disabled.
11 - 18
PH2 - COM
Opening photocell input (NC contact). The photocell intervenes at any time during the opening
of the automation system and stops immediately the movement; the automation system will
continue the opening when the photocell beam is freed. In the event of intervention on closure
(parameter Ph.2. = 0), the automation stops and, when the beam is freed, moves on opening.
In the advanced item
Ph
.
2
., it is possible to select the behaviour of the photocell.
WARNING -
with DIP PH2 on “ON” the input is disabled.
12 - 18
PH1 - COM
Closing photocell input (NC contact). The photocell intervenes at any time during the closing
of the automation system, stops immediately and inverts the movement. The photocell doesn’t
intervene during the opening.
In the advanced item
sp
.
h
. it is possible to select the behaviour of the photocell with the
closed automation.
WARNING -
with DIP PH1 on “ON” the input is disabled.
13 - 18
STOP - COM
Connect the STOP command (NC contact). This input is classified as a safety device; the
opening of the contact stops immediately the automation and it remains blocked up to the
restoring of the state of the input contact.
WARNING -
with DIP STOP on “ON” the input is disabled.
14 - 18
OPEN - COM
Connect the button for the OPEN command (NO contact).
15 - 18
CLOSE - COM
Connect the button for the CLOSE command (NO contact).
16 - 18
PED - COM
Connect the button for the PARTIAL OPENING command (NO contact).
17 - 18
SS - COM
Connect the button for the STEP-BY-STEP command (NO contact).
18
COM
Common for safety and command inputs.
19 - 18
LS1 - COM
Connect the limit switch 1 (NC contact).
20 - 18
LS2 - COM
Connect the limit switch 2 (NC contact).
21
ANTENNA
Connect the antenna
22
SHIELD
Connect the antenna braiding.
23 - 24
MOTOR
Connect the motor.
25 - 26
BATTERY CHARGER
Connect the battery charger card.
Use the clamp 25 for the POSITIVE pole.
Use the clamp 26 for the NEGATIVE pole.
J3
Connector for the Bluetooth module.
J4
Connector for the external memory.
J5
Connector for the optional R1 card.
J7
Connector for the power supply from the transformer.
Summary of Contents for BIOS1 24V
Page 1: ...BIOS1 24V MADE IN ITALY CENTRALINA PER CANCELLI SCORREVOLI 24V...
Page 21: ...BIOS1 24V CONTROL UNIT FOR SLIDING GATES AT 24V MADE IN ITALY...
Page 41: ...BIOS1 24V CENTRAL DE COMMANDE POUR PORTAIL COULISSANT 24V MADE IN ITALY...
Page 61: ...BIOS1 24V CUADRO DE MANDO PARA CANCELAS CORREDERAS 24V MADE IN ITALY...
Page 81: ...BIOS1 24V BESTURINGSEENHEID VOOR SCHUIFPOORTEN 24V MADE IN ITALY...
Page 101: ...BIOS1 24V 24V KAYAR KAPILAR N KUMANDA MERKEZ TALYAN MALI...