5.3 - MALFUNCTION SIGNALLINGS
5.4 - SIGNALLING LED
LED
COLOUR
DESCRIPTION
EDGE
RED
Safety signalling, Led normally ON.
PH2
RED
Safety signalling, Led normally ON.
PH1
RED
Safety signalling, Led normally ON.
STOP
RED
Safety signalling, Led normally ON.
OPEN
GREEN
Led normally OFF. It is turned on when the button is pressed.
CLOSE
GREEN
Led normally OFF. It is turned on when the button is pressed.
PED
GREEN
Led normally OFF. It is turned on when the button is pressed.
SS
GREEN
Led normally OFF. It is turned on when the button is pressed.
LS1
RED
Led is turned on when the limit switch is not activated.
LS2
RED
Led is turned on when the limit switch is not activated.
RADIO
RED
Led ON with a radio transmission or interferences.
POWER ON
GREEN
Led normally ON. It shows the presence of the power supply.
DISPLAY
DESCRIPTION
eme
Memory error: the external memory not installed or not recognised.
ee
x
Memory error during the writing: the value x is a number from 1 to 6. In the event of the error, contact the technical assistance.
eLs
Limit switches error: opening and closing limit switches are busy in the same time
efO
Impact sensor intervention.
eeD
Safety edge intervention.
eph
Malfunctioning of photocells.
eth
Thermical intervention to preserve the control unit.
fuL
Full external memory.
err
Memory error during functions viewing memory location or cancellation of a single transmitter.
NOTE - The visualization of an error on the display persists until the “DOWN” button is pressed or until another command is given.
WARNING - the restore from an
EE
x error must be carried out through one of the 3 buttons of the control unit (UP, MENU or DOWN).
WARNING!
If the supply fuse blows with the motor blocked, check the intervention thresholds of the current sensor. A correct configuration of
the SEN and SEL parameters limits the possibility of failure of the power supply fuse. To avoid the intervention of the supply fuse in the condition of
motor block it is advisable to use the inversion function on the obstacle.
FIG. 5
Summary of Contents for BIOS1 24V
Page 1: ...BIOS1 24V MADE IN ITALY CENTRALINA PER CANCELLI SCORREVOLI 24V...
Page 21: ...BIOS1 24V CONTROL UNIT FOR SLIDING GATES AT 24V MADE IN ITALY...
Page 41: ...BIOS1 24V CENTRAL DE COMMANDE POUR PORTAIL COULISSANT 24V MADE IN ITALY...
Page 61: ...BIOS1 24V CUADRO DE MANDO PARA CANCELAS CORREDERAS 24V MADE IN ITALY...
Page 81: ...BIOS1 24V BESTURINGSEENHEID VOOR SCHUIFPOORTEN 24V MADE IN ITALY...
Page 101: ...BIOS1 24V 24V KAYAR KAPILAR N KUMANDA MERKEZ TALYAN MALI...