3-13
3.4.8 Check Thermo Label of Alternator
Thermo label on the stator irreversibly changes its color from white to brown by reaching or exceeding 212°
F (100
℃
), that signalize overload during operation. Do not overload the generator.
A180802
Remove the trash and dust from the generator inside by
compressed air blowing.
Replace thermo label, if it have changed the color once.
When replacing, contact your nearest dealer.
3.4.9 Check Oil Fence Drain
Oil fence drain port is located at the front of the machine.
A180562
Remove drain plug [A] from the oil fence drain to drain the
condensate.
Check that all condensate is drained, and then re-install the
drain plug.
Drain the condensate into a container [B], and then dispose of
condensate according to the designated regulations.
3.4.10 Check Doors
Pull the handle forward to open the door. Be sure to close the door tightly so that its latch is firmly
caught.
PK0028
Keep the door closed and locked while running the machine.
When opening the door unavoidably, be careful not to touch the
moving s and hot parts. Scalding or serious injury could result.