Installation and hardware
36
Manta Technical Manual V2.7.0
Software
Manta cameras work with the following software options:
•
Vimba Viewer or Vimba SDK
•
Third-party software solutions
Powering up the camera
A camera power adapter for each Manta camera is available from Allied Vision. See
the Specifications chapter for connector definition and voltage specifications.
Powering the camera via Hirose I/O port
Cameras powered by both the Hirose I/O port and the Gigabit Ethernet port use
the power provided by Hirose I/O port only.
Powering the camera via PoE
Cameras powered by both the Hirose I/O port and the Gigabit Ethernet port use
the power provided by Hirose I/O port only.
Please note the following when using PoE accessories with Allied Vision
PoE-capable GigE cameras:
•
PoE-capable Manta cameras conform to the IEEE 802.3af standard for GigE.
•
Category 6 cables are recommended due to being 23 AWG, while Category 5
cables are 24 AWG. This can reduce heating of the cable.
NOTICE
Powering the camera
•
Use only DC power supplies with insulated cases.
•
For all power connections use only shielded cables to avoid EMI.
•
PoE models can source power from:
-
IEEE 802.3af (100 Mbps and 1000 Mbps)
-
IEEE 802.3at compliant PoE power sourcing equipment devices such as
switches, injectors, or network interface controller.
NOTICE
The camera is not intended to be connected to a DC distribution network. The
maximum length for I/O cables must not exceed 30 meters.