Camera interfaces
202
Manta Technical Manual V8.0.1
Triggering during the Readout State
For applications requiring the fastest triggering cycle time whereby the camera
image sensor is exposing and reading out simultaneously, then the user trigger
signal should be applied as soon as a valid trigger ready is detected. In this case,
trigger latency and trigger jitter can be up to one line time since exposure must
always begin on an interline boundary.
For a more detailed description of the trigger concept for advanced users and
special scenarios, see the Triggering Concept
application note.