Guppy PRO Technical Manual
V4.1.2
230
MinValue and MaxValue limits the range the auto gain feature is allowed to use
for the regulation process. Both values are initialized with the minimum and
maximum value defined in the standard GAIN_INQ register.
Changing the auto gain range might not affect the regulation, if the regulation
is in a stable condition and no other condition affecting the image brightness is
changed.
If both auto gain and auto shutter are enabled and if the gain is at its lower
boundary and shutter regulation is in progress, decreasing the lower auto gain
boundary has no effect on auto gain/shutter regulation as long as auto shutter
regulation is active.
Both values can only be changed within the range defined by the standard
GAIN_INQ register.
Autofunction AOI
The table below illustrates the advanced register for autofunction AOI.
Register
Name
Field
Bit
Description
0xF1000370 AUTOGAIN_CTRL
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1 to 3]
Reserved
MaxValue
[4 to 15]
Maximum auto gain value
---
[16 to 19]
Reserved
MinValue
[20 to 31]
Minimum auto gain value
Table 135: Advanced register: Auto gain control
Register
Name
Field
Bit
Description
0xF1000390 AUTOFNC_AOI
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1 to 3]
Reserved
ShowWorkArea
[4]
Show work area
---
[5]
Reserved
ON_OFF
[6]
Enable/disable AOI (see note
above)
---
[7]
Reserved
YUNITS
[8 to 19]
Y units of work area/pos.
beginning with 0 (read only)
XUNITS
[20 to 31]
X units of work area/pos.
beginning with 0 (read only)
Table 136: Advanced register: Autofunction AOI