Guppy PRO Technical Manual
V4.1.2
129
•
Grabbing exactly one image based on the first external trigger.
•
Filling the camera's internal image buffer with one external trigger
without overwriting images.
•
Grabbing an unlimited amount of images after one external trigger
(surveillance)
The figure below illustrates this mode.
The functionality is controlled via bit [6] and bitgroup [12 to 15] of the following
register.
Figure 65: Trigger_Mode_15 (bulk trigger)
External Trigger input, after inverting optocoupler
N x image; N: continuous, one_shot, multi_shot
Trigger_Mode_15 (Bulk trigger)