Appendix
Command reference
This chapter describes the general command reference of the
Pearleye P-007
LWIR
/
Pearleye P-030 LWIR
firmware. It can be output to the camera’s serial
interface by sending the command
?=1
.
IRC-300CL/GE, IRC-320CL/GE, IRC-340CL/GE, IRC-600CL/GE, IRC-640CL/GE,
NIR-300(F)(P)CL/GE, NIR-600PCL/PGE, NIR-610PCL/PGE;
Pearleye P-007 LWIR, Pearleye P-030 LWIR,
Goldeye (CL/P)-008 NIR (Cool) and Goldeye (CL/P)-032 NIR Cool
Series Command Help
===============================================================================
Version...............: Vxx / xx.xx.20xx / AVT GmbH
Referenced Firmware...: Vxx / Vxxxx
General Information
-------------------
Each command consists of a command letter, optionally followed by an equals sign
and a parameter value in hexadecimal number representation. The command
letter is case sensitive. Hexadecimal values are always upper case and are 1 to
4 digits long. The command is activated by sending a carriage return character
([CR], ASCII character number 0x0D). Serial communication operates in echo mode
by default. This means that each character received by the module is echoed
back to the sender.
Example (set Baudrate to 115200 Baud, RS-232 only):
s=A[CR]
After successful execution of the command, the command input character ">" is
output. If any error occurred, somewhere previous to the prompt a question
mark character "?" is displayed.
To query a parameter value, send the corresponding command letter followed by
the equals sign and a question mark character:
s=?[CR]
If the intended action does not need any parameter, it is also sufficient in
most cases - as a shortcut - to send the command letter only, directly followed
by [CR].
Note
This firmware is used in other camera models as well. Thus not
all commands and parameters mentioned in this reference are
useful in conjunction with the
Pearleye P-007 LWIR
/
Pearleye