Camera interfaces
Pearleye Technical Manual
V2.2.0
28
The current (1) which flows through the optocoupler and the integrated drop-
ping resistor should be > 5 mA and should not exceed 20 mA.
Pearleye P-007 LWIR
For continuous periodical trigger the pulse must be at least 100 μs in length and
the periodic time exact 24.96 ms ± 10 μs.
Pearleye P-030 LWIR
For continuous periodical trigger the pulse must be at least 82 μs in length and
the periodic time exact 41.608 ms ± 20 μs.
Sensor temperature too low (pin 12, 13)
As long as the sensor operating temperature is too low, the sensor control out-
put at pin 12/13 remains active (transistor switched on). After the warm-up
period of the camera this output becomes inactive.
Figure 5: Trigger input diagram
Figure 6: Sensor temperature too low
Caution
Pearleye P-007 LWIR / Pearleye P-030 LWIR:
The current
which flows through the optocoupler should not exceed 20 mA
(at 12 V R
v
600
).