Description of the data path
PIKE Technical Manual
V5.0.0
181
Changing color correction coefficients
You can change the color-correction coefficients according to your own
needs. Changes are stored in the user settings.
To change the color-correction coefficients in
SmartView
, go to
Adv3
tab.
Switch color correction on/off
Color correction can also be switched off in YUV mode:
Note
•
A number of 1000 equals a color correction coefficient
of 1.
•
To obtain an identity matrix set values of 1000 for the
diagonal elements an 0 for all others. As a result you
get colors like in the RAW modes.
•
The sums of all rows should be equal to each other. If
not, you get tinted images.
•
Color correction values range -1000 ... +2000 and are
signed 32 bit.
•
In order for white balance to work properly ensure that
the row sum equals 1000.
•
Each row should sum up to 1000. If not, images are less
or more colorful.
•
The maximum row sum is limited to 2000.
Note
Configuration
To configure the color-correction coefficients in an advanced
register: See
Table 161: Advanced register: Color correction
Note
Configuration
To configure this feature in an advanced register: See
161: Advanced register: Color correction
Note
Color correction is deactivated in RAW mode.