IE048-480 Power Supply Installation Guide
57
Wiring the Remote Control (RC) Connector
For background information, refer to “Remote Control Connector for
Turning On or Off the DC Output Connectors” on page 25. This procedure
requires the following:
Two RC connector wires. Refer to Table 10 on page 46 for the
specifications.
Cross-head screwdriver (not provided).
Wire insulator stripper (not provided).
Electronic device for powering on or off the circuit (not provided).
To wire the Remote Control connector, perform the following procedure:
1. Prepare adequate lengths of cables by stripping 8mm of insulation
from the ends.
2. Loosen the two RC connector screws on the top panel and insert the
wires into the connectors. Refer to Figure 14.
Figure 15. Wiring the RC Connector
3. Tighten the screws to secure the wires.
4. Visually inspect the wires for exposed wires and loose strands. Refer
5. Connect the other ends of the wires to the electronic device that will
power on or off the circuit.
Negative (-)
wire
Positive (+)
wire