Chapter 1: Overview
22
AC Input Connectors
You power the IE048-480 Power Supply with AC power on the two AC N
(Neutral) and L (Live) Input connectors on the front panel. The input power
range is 90V to 264V.
Refer to Table 1 for the wire specifications for the AC input connectors.
Warning
Never handle live AC power wires. Always verify that the AC circuit
is powered off before connecting or disconnecting AC power wires
from the AC circuit breaker or power supply.
E 130
Table 1. Wire Specifications for the AC N and L Input Connectors
Wire
Description
Solid Wire
AWG 20 to AWG 10
(Diameter 0.8 to 2.6mm)
Stranded Wire
AWG 20 to AWG 10
(Diameter 0.5 to 5.2mm;
conductor diameter more than 0.18mm)
Insulation Strip Length
8mm