Chapter 3: Installing the Power Supply
52
Connecting the AC Power Wires
The procedure requires the following items:
Two AC power wires. Refer to Table 10 on page 46 for the
specifications.
Cross-head screwdriver (not provided).
Wire insulator stripper (not provided).
Note
When selecting and installing AC power wires, be sure to follow all
industry rules, restrictions, and guidelines that apply to your locale,
such as insulator color, length, and routing.
Warning
Never handle live AC power wires. Confirm that the AC circuit
breaker is powered off before attaching the wires to the circuit break
or power supply. Always connect the wires to the power supply first
and then to the AC circuit breaker.
E135
To attach the AC power wires to the power supply, perform the following
procedure:
1. Verify that the AC circuit breaker is powered off.
2. Loosen the two N (Neutral) and L (Live) screws on the front panel of
the IE048-480 Power Supply and insert the wires into the connectors
on the bottom panel. Refer to Figure 13 on page 53.
3. Tighten the N and L screws to the secure the wires to the power
supply.
4. Visually inspect the wires for exposed wires and loose strands. Refer
5. Connect the wires to the AC circuit breaker.
6. To test and adjust the voltage on the DC output connectors, go to
“Adjusting the Voltage on the DC Output Connectors” on page 54.
Otherwise, go to “Wiring the DC Output Connectors to Powered
Devices” on page 55.
Summary of Contents for IE048-480
Page 1: ...613 002833 Rev A IE048 480 Industrial AC DC Power Supply Installation Guide...
Page 6: ...6 I PDF Allied Telesis alliedtelesis com library...
Page 8: ...Contents 8...
Page 10: ...Figures 10...
Page 12: ...Tables 12...
Page 16: ...Preface 16...
Page 42: ...Chapter 2 Beginning the Installation 42...
Page 51: ...IE048 480 Power Supply Installation Guide 51 Figure 12 Installing the Ground Wire...
Page 53: ...IE048 480 Power Supply Installation Guide 53 Figure 13 Installing the AC Power Wires...