Chapter 3: Installing the Power Supply
46
Power and Control Wires Guidelines
The wire specifications for the connectors on the power supply are listed in
Table 10.
Listed here are guidelines to preparing power and control wires:
Do not strip more wire insulator than specified in Table 10.
Keep the wires as short as possible to avoid unnecessary power
loss.
When using stranded wire, always tightly wrap the wire with your
fingertips. This is to prevent loose strands from touching adjacent
wires and causing electrical shorts. Refer to Figure 9 on page 47.
Table 10. Wire Specifications
Connector
Wire
Description
AC/DC Input
Connectors (N - Neutral
and L - Live)
Solid Wire
AWG 20 to AWG 10
(Diameter 0.8 to 2.6mm)
Stranded Wire
AWG 20 to AWG 10
(Diameter 0.5 to 5.2mm;
Conductor diameter more than 0.18mm)
Insulation Strip Length
8mm
Ground Wire
Solid Wire
Minimum AWG 16
(Diameter 1.3mm)
Insulation Strip Length
8mm
DC Output Connectors
Solid Wire
AWG 20 to AWG 10
(Diameter 0.8 to 2.6mm)
Stranded Wire
AWG 20 to AWG 10
(Diameter 0.5 to 5.2mm;
Conductor diameter more than 0.18mm)
Insulation Strip Length
8mm
RC Connectors or
DC_OK Connectors
Solid Wire
AWG 24 to AWG 16
(Diameter 0.5 to 1.3mm)
Stranded Wire
AWG 24 to AWG 16
(Diameter 0.2 to 1.5mm)
Insulation Strip Length
8mm
Summary of Contents for IE048-480
Page 1: ...613 002833 Rev A IE048 480 Industrial AC DC Power Supply Installation Guide...
Page 6: ...6 I PDF Allied Telesis alliedtelesis com library...
Page 8: ...Contents 8...
Page 10: ...Figures 10...
Page 12: ...Tables 12...
Page 16: ...Preface 16...
Page 42: ...Chapter 2 Beginning the Installation 42...
Page 51: ...IE048 480 Power Supply Installation Guide 51 Figure 12 Installing the Ground Wire...
Page 53: ...IE048 480 Power Supply Installation Guide 53 Figure 13 Installing the AC Power Wires...