70269301
13
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
6. IGNITER DOES NOT SHUT OFF AFTER GAS IGNITION — GAS BURNER
7. HEATING ELEMENT OR BURNER SHUTS OFF PREMATURELY
POSSIBLE CAUSE
TO CORRECT
Tumbler not properly equipped for type of gas
being used.
• Tumbler is equipped for type of gas specified on serial
plate at 0-2,000 feet altitude. Refer to Installation
Manual.
Insufficient gas supply.
• Open partially closed gas shut-off valve, or correct low
gas pressure.
Improperly adjusted burner flame.
• Refer to Adjustment Section for recommended burner
flame adjustment.
Electrode assembly incorrectly installed.
• Check assembly for correct alignment.
Inoperative igniter control.
• Test igniter control and replace if inoperative.
Incorrect wiring.
• Refer to wiring diagram located inside contactor box.
POSSIBLE CAUSE
TO CORRECT
Improper or inadequate exhaust and/or make-up air
system.
• Refer to Installation Manual for exhaust and make-up air
requirements.
Gas Models:
Insufficient gas supply.
• Open partially closed gas shut-off valve, or correct low
pressure.
Gas Models:
Tumbler not properly equipped for type of gas
used.
• Tumbler is equipped for type of gas specified on serial
plate at 0-2,000 feet altitude. Refer to Installation
Manual.
Gas Models:
Improperly adjusted burner flame.
• Refer to Adjustment Section for burner flame adjustment.
Cycling off on high limit thermostat.
Broken, loose or incorrect wiring.
• Refer to wiring diagram located inside contactor box.