40
70269301
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
42. STOVE HIGH LIMIT THERMOSTAT
(Gas Models)
a. Remove two screws holding thermostat and
bracket to rear side of stove. Refer to Figure 4.
b. Remove two screws holding cover to mounting
c. Disconnect wires from thermostat.
d. Remove two screws holding thermostat to
mounting bracket. Refer to Figure 5.
Figure 4
JUNCTION
BOX
CONDUIT
NUT
SCREWS
STOVE
HIGH LIMIT
THERMOSTAT
T025SE1A
Figure 5
TU026-SV
STOVE
HIGH LIMIT
THERMOSTAT
MOUNTING
BRACKET
COVER
SCREWS
SCREWS