Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
m. Remove locknut and jam nut holding fan on
motor shaft. Refer to Figure 18. Pull fan off
motor shaft.
NOTE: Fan is keyed to motor shaft and may have to
be removed using a puller. Look for a spacer washer
at the bottom of the fan keyway. Take care to avoid
losing or damaging the spacer washer.
n. Remove spacer washer from motor shaft. Refer
o. Loosen two setscrews holding motor pulley to
motor shaft. Refer to Figure 18. Remove motor
pulley.
NOTE: A puller may be required to remove pulley
from motor shaft.
NOTE: After installing motor and fan assembly,
adjust belt.
Figure 17
T045SE3A
LOWER
GUIDE RAIL
BOLT
MOTOR
AND FAN
ASSEMBLY