To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 5
Service Procedures
IMPORTANT: References made to the left or right
hand direction are taken from the operator’s
position facing the front of the tumbler.
30. CONTROLS
a. Unlock and remove control panel.
b. Remove two screws holding control assembly
to tumbler. Pivot control to left, disconnect wire
harness plugs and remove control assembly.
IMPORTANT: When handling electronic controls,
use a ground wrist strap. Due to the sensitivity of
electronic controls, careful handling is required.
Wrist strap, cord and alligator clip are designed to
carry away any electrostatic charge from your body
and to direct charge to an available ground. By
using this static protection device, potential
electrostatic discharge problems associated with
handling of electronic control will be minimized.
Always handle electronic control by its metal edges.
If a wrist strap is not available, touch tumbler while
it is plugged in before handling control to dissipate
any charge.
31. PUSH-TO-START SWITCH
a. Remove control.
b. Disconnect wires from switch terminals and
compress locking tabs to remove switch.
NOTE: Refer to wiring diagram when rewiring
switch.
32. COOLING, DRYING, OR RUN LIGHT
a. Remove control.
b. Disconnect light wire leads.
NOTE: On Coin Meter Models, the run light white
lead must be joined to the wire harness white lead
using a double spade connector. Remove the single
spade lug from the replacement run light white
wire.
c. Compress locking tabs on sides of light and
push light out through front of control.
NOTE: Refer to wiring diagram when rewiring