70269301
49
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
57. TRUNNION SHAFT ASSEMBLY
a. Remove cylinder assembly.
b. Remove the four washers and nuts holding
trunnion shaft assembly to rear of cylinder.
IMPORTANT: When installing trunnion assembly
on cylinder, the cylinder and shaft must be aligned.
Refer to Figure 15 for an example of how to check
for proper alignment of the shaft and cylinder.
Measure the distance between the center of the
trunnion shaft and the outer rim of the cylinder at
the four points shown. If any measurement is lower
than the highest point, place shim or shims
(M401402) between trunnion channel and cylinder
back until the measurement is equal to the highest
point.
NOTE: After installing cylinder and shaft, adjust
cylinder clearance. Refer to Adjustments section.
c. Reinstall drive guard on tumbler.
Figure 15
MEASURE AT
FOUR POINTS
CYLINDER
TAPE
MEASURE
TRUNNION
ASSEMBLY
T089SE3C