46
70269301
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
54. DRIVE BELT
Nonreversing Tumblers
Refer to Figure 24.
a. Disconnect electrical service to tumbler.
b. Remove drive guard. Refer to Figure 10.
Remove two screws holding belt guard
assembly to motor bracket. Refer to Figure 12.
Remove belt guard.
c. Loosen cap screws on idler housing. Drop idler
housing to bottom of slots by loosening jam nut
by turning adjustment screw down.
d. Remove lower bolt and nut from guide rail.
Hinge guide rail out and slip belt out from
under guide rails.
e. Slip new belt under guide rail and onto sheave
and motor pulley.
Figure 11
AIRFLOW
SWITCH
MOUNTING
SCREWS
SWITCH
LEVER
SWITCH
BOX
MOUNTING
BRACKET
T037SE1A
Figure 12
SCREWS
BELT
GUARD
TU039-SV
MOTOR
BRACKET